Search...

⌘K

BASE BL-B01

Central intelligence hub for the B-LINK network. Full two-way communication with all POINT + MINI devices. Integrates to access-control systems and B-SENSE tracking. 16 outputs + 8 inputs, LCD status display, 12-24V powered (Solar compatible).

Short Description

The BASE is the central hub of the B-LINK ecosystem — receiving supervised wireless events from POINT devices and interfacing them into existing security and access control infrastructure.

It provides substantial I/O expansion, onboard status display, flexible network integration options and secure 256-bit encryption — enabling cable-free system extensions across complex sites.

Main Applications

  • Large site access control expansion

  • Distributed alarm input and relay management

  • Remote gate and perimeter integration

  • Industrial monitoring and automation

  • Control room event aggregation

Inputs

8 x Physical inputs
Progressive monitoring and alarm mapping

Outputs

16 x Configurable outputs
Compatible with alarm panel resistance profiles

Specifications

Category

Detail

Communication

Two-way B-LINK encrypted

Frequency

433 MHz & 2.4 GHz

Wireless range

>2 km line-of-sight*

Power supply

10–15 VDC

Current consumption

250 mA @ 12 V typical

Display

OLED screen for device status

Configuration

Web GUI + DIP switches

Supervision

Full supervision of all linked devices

Encryption

256-bit

Integration

Alarm/access outputs, MQTT messaging

Dimensions (mm)

51 × 71.5 × 22

Weight

300 g

Mounting

Indoor cabinets, comms rooms

Category

Detail

Communication

Two-way B-LINK encrypted

Frequency

433 MHz & 2.4 GHz

Wireless range

>2 km line-of-sight*

Power supply

10–15 VDC

Current consumption

250 mA @ 12 V typical

Display

OLED screen for device status

Configuration

Web GUI + DIP switches

Supervision

Full supervision of all linked devices

Encryption

256-bit

Integration

Alarm/access outputs, MQTT messaging

Dimensions (mm)

51 × 71.5 × 22

Weight

300 g

Mounting

Indoor cabinets, comms rooms

Set-Up Guide

Connect 12 VDC power

  • Ensure Dip Switch 1 & 2 are down for Access Point + UI active

  • Connect to Wi-Fi: BLINK 11
    Password: wireless

  • Go to 192.168.1.1

  • Login: blink / wireless

  • Set Site ID + Receiver ID

  • Configure heartbeat time and radio power

  • Set output resistances to match alarm system requirements

  • Save changes

  • Configure network or MQTT (optional)

Troubleshooting

Issue

Action

No devices connecting

Confirm radio enabled + correct Site/Receiver IDs

No GUI access

Check Dip Switch 2 = UI enabled

Weak field signal

Adjust radio power (Setup Step 009)

Incorrect alarm responses

Verify output resistance settings (Setup Step 010)